切换至 "中华医学电子期刊资源库"

中华临床实验室管理电子杂志 ›› 2014, Vol. 02 ›› Issue (04) : 15 -18. doi: 10.3877/cma.j.issn.2095-5820.2014.04.004

观点

酶学参考测量体系的量值溯源探讨
王惠民1,(), 林景星2, 季伙燕1, 胡冬梅3, 吕京3, 陈宝荣4, 王建新1, 沈蕾1   
  1. 1.226001 南通大学附属医院检验中心
    2.福建省计量科学研究院
    3.中国合格评定国家认可中心
    4.北京航天总医院检验科
  • 收稿日期:2014-11-04 出版日期:2014-11-28
  • 通信作者: 王惠民
  • 基金资助:
    国家质量检测总局公益性行业科研专项经费项目资助课题(201210066)南通市科技项目资助课题(HS2012009)

Metrological traceability of reference system for enzymology

Huimin Wang1,(), Jingxing Lin1, Huoyan Ji1, Dongmei Hu1, Jing Lyu1, Baorong Chen1, Jianxin Wang1, Lei Shen1   

  1. 1.Center of Laboratory Medicine,Affiliated Hospital of Nantong University,Nantong 226001,China
  • Received:2014-11-04 Published:2014-11-28
  • Corresponding author: Huimin Wang
引用本文:

王惠民, 林景星, 季伙燕, 胡冬梅, 吕京, 陈宝荣, 王建新, 沈蕾. 酶学参考测量体系的量值溯源探讨[J/OL]. 中华临床实验室管理电子杂志, 2014, 02(04): 15-18.

Huimin Wang, Jingxing Lin, Huoyan Ji, Dongmei Hu, Jing Lyu, Baorong Chen, Jianxin Wang, Lei Shen. Metrological traceability of reference system for enzymology[J/OL]. Chinese Journal of Clinical Laboratory Management(Electronic Edition), 2014, 02(04): 15-18.

酶学参考实验室通过量值溯源,确保与其测量结果及相关工作条件溯源至现有最高计量学等级,包括对能直接溯源至国际单位制(international system of units,SI)导出单位的酶催化活性浓度,及与测量有关仪器设备主要性能参数的量值溯源。 本文以肌酸激酶参考测量程序为例,对其量值溯源,涉及的相关因素有时间、 容量、 温度、 分光光度计波长和透光度、 比色杯光径、 酸度计pH、质量等。 以阐明酶活性浓度量值溯源过程中应注意事项,以尽量避免溯源过程中可能出现的偏差。

Reference laboratory of enzymology ensure the working conditions associated with the measured related to the highest stated reference standard through metrological traceability,includes the activity concentration of kinase which can be directly traced to international system of units(SI)units and performance parameters of some related main equipment. Taking reference procedure for creatine kinase as an example,the article describes the traceability process of time,volume,temperature,wavelength and penetrability of spectrophotometer,the inner diameter of colorimetric cup,pH and quality for clarifying the matters need attention in the traceability process of concentration measurement for enzymatic activitye,which is conductive to make the metrological traceability more accurate.

1
ISO. In vitro diagnostic medical devices-measurement of quantities in biological samples-metrological traceability of values assigned to calibrators and control materials. ISO 17511[S]. Geneva,Switzerland:International Organization for Standardization,2003.
2
ISO. In vitro diagnostic medical devices-measurement of quantities in biological samples-metrological traceability of values for catalytic concentration of enzymes assigned to calibrators and control materials.ISO 18153[S]. Geneva,Switzerland: International Organization for Standardization,2003.
3
ISO.Quantities and units Part 1:General. ISO 80000-1:2009[S].Geneva,Switzerland:International Organization for Standardization,2009.
4
Siekmann L,Bonora R,Burtis CA,et al. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes[J].Clin Chem Lab Med,2002,40(6):631-634.
5
中国质检出版社. 中华人民共和国国家计量检定系统表框图汇编.5版[M].北京: 中国质检出版社,2011.
6
CNAS. 检测和校准实验室能力认可准则在酶学参考测量领域的应用说明[S].CNAS-CL33: 2011.北京: 中国合格评定国家认可委员会,2011:1-27.
[1] 何甜甜, 要文聪, 刘珊玲, 王和, 张雪梅. 血样低温放置时间对黏多糖贮积症酶学检测的影响[J/OL]. 中华妇幼临床医学杂志(电子版), 2021, 17(05): 566-573.
[2] 彭玲, 吴红, 宛仕勇, 陈斓, 叶子青, 周静. 胶原酶软膏联合水胶体敷料应用于深Ⅱ度烧伤创面治疗的效果观察[J/OL]. 中华损伤与修复杂志(电子版), 2024, 19(06): 511-516.
[3] 江志鹏, 马宁, 李英儒, 宗振, 侯泽辉, 甘文昌, 陈双. Ras蛋白特异性因子RASGRF1在结直肠癌组织中的表达及影响因素[J/OL]. 中华普通外科学文献(电子版), 2016, 10(04): 237-240.
阅读次数
全文


摘要